Ladder 2 Wire CMU Size: 6''

Wire-Bond

SKU / Product InfoQuantity
WB-L2WEHD6-HDG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 3/16" CMU Size: 6'' Hot Dip Galvanized
WB-L2WEHD6-MG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 3/16" CMU Size: 6'' Mill Galvanized
WB-L2WEHD6-SS
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 3/16" CMU Size: 6'' Stainless Steel
WB-L2WHD6-HDG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 9 Gauge CMU Size: 6'' Hot Dip Galvanized
WB-L2WHD6-MG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 9 Gauge CMU Size: 6'' Mill Galvanized
WB-L2WHD6-SS
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 9 Gauge CMU Size: 6'' Stainless Steel
WB-L2WS6-HDG
16" O.C. Side Rods: 9 Gauge (.148 in) Cross Rods: 9 Gauge CMU Size: 6'' Hot Dip Galvanized
WB-L2WS6-MG
16" O.C. Side Rods: 9 Gauge (.148 in) Cross Rods: 9 Gauge CMU Size: 6'' Mill Galvanized
WB-L2WS6-SS
16" O.C. Side Rods: 9 Gauge (.148 in) Cross Rods: 9 Gauge CMU Size: 6'' Stainless Steel

Quick Overview


  • 16" O.C. ladder design positions cross rods on web of block to allow core clearance.
  • Simplifies rebar installation; centering utilizes strength of grout.
  • Allows unrestricted flow of grout or loose fill insh6ation into CMU cells.
  • Minimizes re-setting of joint reinforcement around rebar.
  • Improves resistance to shrinkage cracking.
  • Provides stronger bond with cross rods in web of block.
  • Less time devoted to rebar installation, grout pouring.
  • Meets ASCE/ACI 530 building code requirements for masonry structures and ASTM A 951 (standard specification for masonry joint reinforcing).
Interested in this item or want more information?

Hours:

Phone: 610-992-9700

Email: sales@gattimorrison.com

Can't find what you want? Give us a call and we can help you find it.

Details


Ladder design is a prefabricated reinforcement for embedment in the horizontal mortar joints of masonry. It is manufactured in 10’ 8” lengths from wire conforming to ASTM A 82 / A82M for cold drawn steel wire. It consists of two or more parallel and deformed longitudinal wires welded to a perpendicular cross wire spaced 16" O.C. Out-to-out spacing is approximately two inches less than the nominal thickness of the wall.

Gauges:

  • Standard Weight ( 9ga x 9ga).

  • Heavy ( 3/16" Side Rods x 9ga Cross Rods).

  • Extra Heavy (3/16" Side Rods x 3/16" Cross Rods).


  • Available Finishes:

  • Mill Galvanized

  • Hot Dip Galvanized

  • Stainless Steel
  • Additional Information


    Manufacturer: Wire-Bond

     
    © 2024 Gatti Morrison